Linear pump 361 ST AC
Technical Data
Operating Voltage |
: |
230V 50Hz |
Motor type |
: |
VibratingArmatureDrive |
Head Configuration |
: |
Pressure |
Medium |
: |
Gas |
Power at rated load |
: |
14 Watt |
|
|
|
Max. Pressure |
: |
0,2 bar |
Constant Pressure |
: |
0,2 bar |
Flow |
: |
4,8 l/min |
Current Cunsumption |
: |
0,09 A |
Protection class |
: |
IP 54 |
Ambient temperature |
: |
10°C to +40°C |
Power supply |
: |
AC |
Weight |
: |
0,9 Kg |
|
|
|
Inlet |
: |
Integrated filter |
Outlet |
: |
Pressure port |
Electrical connection |
: |
1 m cable with Euro-plug |
Mounting |
: |
Rubber feet |
Features
› Low power consumption
› Operating voltage 230V AC
› Oil-less
› Maintenance free
› Low vibration
› Long life
› Natural pressure limitation
› Continuous operation
› Very low noise
Typical Applications
› Bubble Tubes
› Gas/Particle Analysis
› Air Mattress
› Compressions Therapy
Dimensions in mm (inch)
Flow
Documents for Download
Data Sheet
Technical modifications reserved