Side channel G-BH1 500 7A H26
Vacuum pump & Compressor
Single stage with three phase asynchronous motor
Technical Data
Frequency | 50 Hz | 60 Hz |
Output | 1,6 kW | 2,1 kW |
Voltage | 200-240V ▲ / 345-415V Y | 220-275V ▲ / 380-480V Y |
Current | 7,5 A ▲ / 4,3 A Y | 7,6 A ▲ / 4,4 A Y |
Sound pressure level | 64 dB(A) | 70 dB(A) |
Max. differential pressure VACUUM | -200 mbar | -220 mbar |
Max. differential pressure COMPRESSOR | 190 mbar | 210 mbar |
Motor protection class | IP55 |
Thermal class | F |
Suction and discharge port | on motor side (standard) |
Weight | approx. 23 Kg |
Dimensions in mm
Phase | A | B | C | D | E | F | G | H | J | K | L | M | N | O | P | Q | ø R | S |
3 ~ | 334 | 337 | 120 | 260 | 295 | 346 | 185 | 175 | 128 | 115 | 155 | 96 | 87 | 48 | 55 | 83 | 14 | 4 |
U | V1 | V'1 | ø X | Y x Z | X-Holes | W |
M 8 x 17 | M 25 x 1,5 | M 16 x 1,5 | 200 | M 8 x 20 | 0°/120°/240° | 32 |
Features G-BH 1
Classics with innovative technology With their high inlet volume flow up to 2,500 m³/h and a differential pressure of up to 780 mbar, our low noise G-BH1 side channel blowers have earned their reputation. They are reliable, low maintenance and durable. They deliver 20,000 operating hours without fail and are virtually maintenance free.
When used with a frequency converter the performance of the G_200 pumps and compressores can be increaseddddd considerably.
The 2BH1 machines are UL/CSA approved and can be used without further testing all over the world. Motors comply with DIN EN 60034 and have IP 55 protection.